Abstract
Introduction
To determine the incidence of pressure injuries caused by medical devices in the pediatric intensive care unit.
Methods
It is a prospective study of observational analytical type. Strengthening the Reporting of Observational Studies in Epidemiology guide was used in the study. It was conducted with 117 children in the pediatric intensive care unit of a gynecology and pediatrics hospital in the Southeastern Anatolia Region of Turkey between 01.01.2023 and 30.06.2023. In the study, data were collected using the information form together with the Braden and Braden Q scale. Data were analyzed with SPSS 25.0 statistical analysis program.
Results
It was determined that 53% of the children included in the study were male, 24.8% were hospitalized due to neurological diseases, 55.6% had chronic diseases and 74% were fed enterally. It was determined that the average age of the children was 37.46±40.98 (months), the average body weight was 15291.45±17364 (g), and the average height was 83.06±23.85 (cm). In the study, pressure injuries caused by medical devices occurred in 26.5% of the children, 35.7% of these pressure injuries caused by medical devices were 1st degree, 17.6% were ungraded wounds (Mucosa), 48.5% of the children were injured. It was observed that 2 injuries occurred in 100,000 children and 44.4% of the children had 5 or more medical devices. It was determined that the average number of days for injuries caused by medical devices was 38.63±41.91 days, the frequency of injuries per 1000 patient days was 14.98, and the rate of injuries caused by medical devices was 5.9%.
Conclusion
The study showed that a high rate of pressure injuries occurred due to medical devices. Appropriate care should be planned for children admitted to pediatric intensive care units by assessing the risk of injury caused by medical devices.
Introduction
With scientific progress and technological innovations, the role of technology in the treatment and care of patients has increased. The use of technology in treatment and care services causes some problems as well as benefits. One of these problems is medical-device related pressure injuries (MDRPI) and accordingly, the disruption of skin integrity.1 MDRPI is defined as localized injuries to the skin or subcutaneous tissues, including the mucosa, caused by intense/continuous pressure exerted on the skin/mucosa by medical instruments used for diagnosis and treatment purposes. The most important difference between a pressure injury (PI) and a MDRPI is that the force exerted by an instrument strapped or taped to the body, not by body weight, plays a significant role in the development of a MDRPI.2-5 While medical instruments alone can cause skin-damaging pressure, they can also alter the microclimate of the skin by creating heat and moisture between the equipment and the skin, which can increase the risk of skin deterioration. In the first large-scale study emphasizing the importance of MDRPI, the incidence and prevalence of pressure injuries were examined by following 2.178 adult patients over an eight-month period.6 As a result of the study, it was reported that the rate of hospital-acquired pressure injuries was 5.4% and 34.5% of these injuries developed in association with medical instruments. It was also stated that if a patient had a medical instrument, the likelihood of developing any type of PI would be 2.4 times higher. The first integrative study examining the factors associated with MDRPI in hospitalized children was conducted by Murray et al.1 in 2013. The study included 32 articles with evidence levels ranging from IV to VII and a total of 2,745 sick children. A total of 18 medical devices causing pressure injuries were identified and 138 pressure injuries caused by medical devices were mentioned.1 In 2016, the National Pressure Ulcer Advisory Panel defined MDRPIs as those resulting from the use of medical instruments for diagnostic or therapeutic purposes and as PIs in which the shape of the injured part was consistent with the medical instruments.2 In 2017 position paper, the Wound, Ostomy and Continence Nurses’ Society has stated that medical instruments can cause PIs in all age groups, primarily in acute intensive care settings, and in long-term care settings and home care. It has made a number of recommendations, including the identification of risk factors as the basis for the development of risk assessment tools, best practices, quality improvement interventions, and safe materials, and the conduct of research to prevent the occurrence of MDRPI in all health care settings.7, 8 In February 2019, an international group of medical, clinical and bioengineering experts agreed that medical instruments or non-medical objects that came into contact with or compressed the skin could cause cellular and tissue-level disruption, based on their evidence-based reviews of the etiology, assessment, prevention and management of MDRPI. In their statement, the instruments most commonly associated with MDRPI and the biomechanical causes of the risks they posed were identified and discussed. They also assessed which bioengineering designs and technologies could be used to prevent MDRPI, how to alleviate the frictional force on tissues and how to optimize the microclimate.3
MDRPIs are a significant problem in the pediatric population. In studies evaluating the incidence and risk factors of pressure injuries in hospitalized infants and children, it has been reported that all PIs are largely related to the use of medical instruments, and the incidence of MDRPI varied between 7% and 36.2%. 3, 4, 9-15 In studies conducted in Turkey, it has been reported that the prevalence of MDRPI in pediatric age groups ranged between 6.8% and 21%. 9, 12
The types and numbers of medical instruments frequently used in pediatric clinics vary according to the patient population, which creates variability in instrument-related risk. Data monitoring for MDRPI may contribute to more effective evaluation of strategies to prevent such adverse events and to the improvements in care. Today, research carried out to determine trends in the prevalence and incidence of MDRPI is becoming more important. The incidence study on pediatric MDRPI shows the likelihood of occurrence of MDRPI, helps to identify its causes and provides a more accurate understanding of the quality of care for hospitalized patients. The use of MDRPI rate per 1000 device-days for each device type is a reliable measure that reveals the true extent of the causes as it also addresses the time factor. The aim of this study was to examine the incidence of MDRPIs in a pediatric intensive care unit (PICU) and to determine the relationship between the medical instruments used and MDRPIs, the factors causing this health problem and the risk situations.
Materials and Methods
Research Type
It is an observational analytic type prospective study. The study was performed according to the Strengthening the Reporting of Observational Studies in Epidemiology guideline used in observational studies.16
Study Population and Sample
The sample of the study consisted of children hospitalized in the PICU of a maternity and child hospital located in the Southeastern Anatolia Region of Turkey between 01.01.2023 and 30.06.2023 (for 6 months). During the specified period, 142 children were hospitalized in the PICU; however, 3 of these children were excluded from the study because they had PI when they arrived at the unit, 2 due to having skin diseases, and 20 due to being hospitalized daily. The study was conducted with 117 children who were hospitalized in the PICU and met the inclusion criteria.
Children between the ages of 1 month and 18 years, who did not have any skin problems, who had at least one medical device, and whose parents gave written and verbal consent were included in the study. Day cases and those with skin diseases were not included in the study.
Data Collection
The data of the study were collected by the researcher, who was working as a nurse in the PICU, by using the Braden Q scale, Braden risk assessment scale, information form including clinical and socio-demographic information of the children and MDRPI staging form.
Braden Q Scale
Curley et al.10 developed the Braden Q scale by adapting the Braden scale for adults to children. They added tissue perfusion and oxygenation items to the Braden scale. The scale is an assessment tool used to evaluate the risk of pressure ulcer development in children aged 28 days to 5 years. Each item in the scale is scored from 1 to 4. For the interpretation of the scores obtained from the scale, 16-23 points are considered as moderate risk for PI development, 13-15 points as serious risk, 10-12 points as high risk, and 9 and lower points as very high risk.10 The Turkish validity and reliability study of the scale was conducted by Güneş and Törüner17and the Cronbach alpha value of the scale was found to be 0.80.
Braden Risk Assessment Scale
It was developed by Braden et al. in 1987. The scale consists of 6 subscales: Sensory perception, skin moisture, activity, mobility, friction and shear, and nutritional status. It was adapted to the Turkish population by Oğuz and Olgun18 and then for the second time by Pınar and Oğuz.19 The total score of the scale ranges from 6 to 23; 12 points and below are considered very risky, 13-14 points are considered moderately risky and 15-16 points are considered low risky. In the present study, risk assessment of children over 5 years of age was performed with the Braden scale.18, 19
Information Form
It was composed of 17 questions formed by reviewing the literature including information on gender, body weight, height and clinical characteristics etc. of the children.10, 13, 18, 19
MDRPI Staging Form
The form was developed by the investigators according to the staging form accepted by the National PI Advisory Panel.2 Skin pressure injuries were staged using the MDRPI staging system. For mucosal injuries, the staging system for skin pressure injuries was not applied, and they were considered as “mucosal membrane pressure injury”.
Statistical Analysis
The data obtained in the study were uploaded to the SPSS 25.0 program and analyzed. Frequency, percentage, mean, minimum, maximum and standard deviation analyses were performed. In addition, MDRPI per 1000 patient days was calculated using the formula (number of wounds formed/total number of hospitalization days * 1000).
Ethical Dimension of the Study
Before starting the study, ethics committee approval was obtained from the Ethics Committee of a Kilis 7 Aralık University with the decision numbered 2021/11-6 and research permission was obtained from the provincial health directorate to which the hospital was affiliated. Written and verbal consents were obtained from the families of the children for inclusion in the study. The study was conducted in accordance with the Declaration of Helsinki.
Results
Demographic and clinical characteristics of the pediatric patients evaluated in this study are summarized in Table 1. It was observed that 53% of the children participating in the study were male, neurological diseases (24.8%), cardiovascular problems (19.7%) and respiratory system disorders (17.1%) were found to be prominent among the reasons for hospitalization, and the presence of chronic diseases was determined in 55.6%. When the nutritional status was analyzed, it was observed that most of the children (74.5%) were fed with enteral nutrition. The mean age of the children was 37.46±40.98 months, the mean body weight was 15291.45±17364 g and the mean height was 83.06±23.85 cm. The mean values for the vital signs of the children were as follows: heart rate 119.66±20.63 min, respiratory rate 28.81±6.43 min, systolic blood pressure 102.72±12.63 mmHg and diastolic blood pressure 61.09±12.57 mmHg. The mean oxygen saturation, hemoglobin and serum albumin values of the children included in the study were 98.56±1.90%, 10.71±1.09 g/dL and 34.3±3.67 mg/dL, respectively. The mean Braden Q scale score was 10.36±1.90, the mean Braden scale score was 10.77±2.46 and the mean duration of hospitalization was 31.94±37.55 days (Table 1).
It was detected that a total of 941 medical devices were used in pediatric patients hospitalized in PICU. When the distribution of these devices was analyzed, it was seen that pulse oximetry probe (POP), blood pressure cuff and infusion pump were used in all of the children and the ratio was 12.4% for each of them in the total devices used. These devices were followed by electrocardiography (ECG) electrodes (12.2%), nasogastric catheter (NGS) (11.8%), and foley catheters (10.3%). Endotracheal tube (ETT) and intravenous catheters were used at similar rates (7.2%). These devices were followed by central venous catheters 5.4%, tracheostomy tubes 3.6%, nasal oxygen cannulas 1.8%, continuous positive airway pressure (CPAP) masks and heating devices 1% each, hemodialysis catheters 0.7% and gastrostomy tubes 0.6%, respectively (Table 2).
It was determined that 26.5% of pediatric patients treated in the PICU had MDRPI. When the number of MDRPIs was analyzed, it was found that 38.6% of the children had one MDRPI, 48.4% had two MDRPIs, 6.5% had three MDRPIs and 6.5% had four MDRPIs and the total number of MDRPIs was 56. Of these 56 MDRPIs, 35.7% were classified as grade 1, 39.2% as grade 2 and 7.1% as grade 3. The rate of ungraded PIs that developed in the mucosa was found to be 18.0%. When the number of medical instruments used in each child was analyzed, it was determined that 12.8% had two, 18.9% had three, 23.9% had four, and 44.4% had five or more medical instruments. The mean number of days of MDRPI development was 38.63±41.91 days and the incidence of injuries per 1000 patient days was 14.98. In addition, the ratio of the number of wounds according to the number of medical devices was determined as 5.9% (Table 3).
When Table 4 was analyzed, it was observed that the most common causes of grade 1 MDRPI were POP, ECG electrodes, similarly NGS and tension cuff, respectively. Grade 2 injuries were caused by ETT tube application, NGS and POP in equal rates, ECG electrodes and central venous catheter applications in similar rates, respectively. Grade 3 injuries were lower in number and were equally associated with NGS, POP and ECG electrodes. The causes of MDRPI that could not be evaluated due to the absence of mucosal injury were NGS, EET tube and nasal oxygen cannula, respectively.
In the study, 23.0% of NGS-induced injuries were determined as grade 1, 30.8% as grade 2, 7.7% as grade 3 and 38.5% as ungradable wound mucosa. Of the ETT tube-induced injuries, 30.0% were ungradable wound mucosa, 60% were grade 2 and 10% were grade 3. Of the POP-induced injuries, 50% were grade 1, 40% were grade 2 and 10% were grade 3. Of the injuries caused by ECG electrodes, 71.4% were grade 1 and 28.6% were grade 2. Of the injuries caused by tracheostomy cannula, 50% were grade 1 and 50% were grade 2. In both types of central venous catheter and CPAP mask injuries, 50% were grade 1 and 50% were grade 2. All of the injuries caused by nasal oxygen cannula were found to be ungradable wound mucosa and all of the injuries caused by gastrostomy tube were found to be grade 3. 100% of the Foley catheter injuries were grade 2 (Table 4).
Discussion
In the study conducted to determine the incidence of MDRPI in PICU, patients who met the inclusion criteria were observed by the researcher for 6 months between 01.01.2023 and 30.06.2023 and the data obtained were analyzed and discussed.
It was determined that most of the children followed up in the study were male, the mean age was 3 years, the leading reason for hospitalization was neurological diseases, more than half of them had chronic diseases and the majority of them were enterally fed. Their clinical values were within normal ranges and they were found to be at risk according to the evaluation of Braden scales. It is reported that most of the children hospitalized in PICUs are under 5 years of age, those with chronic diseases have more severe disease course and neurological patients should be hospitalized to protect the brain. It is known that patients hospitalized in PICUs are at risk for pressure injuries due to their poor clinical status, the device they are attached to or their inability to move due to unconsciousness. We can say that the fact that the clinical values of the children in the study were within normal limits was due to the treatment in the clinic. Semerci et al.12 conducted a descriptive and retrospective study on 6.350 children, using data obtained in PICUs, Neonatal Intensive Care Units (NICUs) and Pediatric Clinics and they found that the prevalence of PI was 2.25% in all patients and 6.04% in PICU patients. They reported that the majority of the children were boys mostly in the age range from 0 month to 12 months and a total of 143 pressure injuries occurred in 59 children. At the same time, it was reported that medical instrument-induced pressure injuries occurred in 21% of patients hospitalized in PICU.12 In a study performed by Başbakkal et al.9 medical instrument-induced pressure injuries were reported to have occurred in 96 patients. It was determined that the majority of the children included in the study were male, 56 medical instrument-induced pressure injuries occurred in 31 children and NG, ETT and POP mostly caused pressure injuries. Children hospitalized in the PICU are compatible with previous studies in terms of the occurrence of pressure injuries caused by medical instruments.
In the study, the incidence of injuries per 1000 patient days was 14.98 and the number of medical instruments was 5.9%. In a study by Başbakkal et al.9, it was reported that the incidence of injuries was 43.4 per 1000 patient days and 6.8% of medical instruments caused pressure injuries. In a study by Shimura et al.20, it was reported that the occurrence of pressure injuries caused by medical instruments was 4.6 per 1000 patient days. In another study conducted in the United States of America in 8 hospitals and with 625 children, they found that the occurrence of medical instrument-induced pressure injuries was in 7 days per 1000 patient days.13 The difference in medical instrument-induced injuries per 1000 patient days in the studies may be thought to be due to the conditions of the patients followed in countries, regions and clinics.
In the study, it was determined that NG, ETT and POP were the first three instruments causing medical instrument-related injuries. It can be thought that NG, ETT and POP are the most commonly used medical devices in PICUs, and at the same time, the areas where these devices are attached are sensitive. It is estimated that MDRPI develops due to the sensitivity of the regions where the NG and ETT tubes are attached and it is very difficult to prevent the pressure of these instruments attached there. Başbakkal et al.9 found that NG, ETT and ECG electrode were the most common causes of pressure injuries caused by medical devices. Kim et al.21 reported that the rate of pressure injuries related to medical instruments was 11.9% in a study on 184 pediatric patients in the PICU of a university hospital in Korea and 54.2% of these injuries were caused by intubation tubes, 37.5% by high-flow oxygen cannulas and 8.3% by saturation probes. In a 5-year study conducted nationwide in pediatric and NICUs, Ventilacion et al.22 found that 50% of pressure injuries were caused by nasal intubation tubes. In our study and other studies conducted in the literature, it was observed that the instruments causing MDRPIs were similar.
These rates vary between 1% and 27% in PICUs and NICUs.23, 24 Kohr and Curley23 found that the rate of pressure-related injuries in pediatric patients was 27.7% in a study conducted in Switzerland. In a study conducted by Pellegrino et al.24 on 523 children in different hospitals in Brazil, they reported a hospital-acquired PI rate of 7.1%; 25% of pressure injuries were associated with medical devices and 94% were observed in children with medical devices. In a study conducted in Turkey, it was reported that the rate of medical device-related pressure injuries was 37.5%.9 In the present study, the rate of medical device-related injuries was 26.5%. The high incidence of medical instrument-induced pressure injuries in children is thought to be due to the lower resistance of children’s skin to pressure.
In a study by Başbakkal et al.9 it was reported that 22.9% of children had 1st degree pressure injuries, 89.5% of children with injuries had 5 or more medical devices attached, and 33.3% of medical device-induced pressure injuries were caused by NGS. In another study, it was reported that 24% of medical device-induced pressure injuries in children were 1st degree and most injuries were caused by NGS.25 In the study, it was observed that 50% of the medical instrument-induced pressure injuries in children were grade 1 and NG was the most common medical instrument causing pressure injuries. In our study and in the literature, it is seen that NG is the medical instrument that most frequently causes MDRPIs. Since there is no adipose tissue under the skin of the nose, it can be stated that even the smallest pressure can prevent circulation and cause injury.
Study Limitations
The study has some limitations. These limitations include the fact that the study was conducted in a certain hospital in a certain region, that health professionals working in the clinic were not investigated because only patients were examined in the study, and that other reasons other than medical devices were not addressed.
Conclusion
As a result of the study, it was observed that MDRPIs developed at a high rate in children. NGS, ETT tubes, POP and ECG electrodes, which are frequently used in PICUs, were found to be the most common causes of MDRPIs. The strength of the study is that it will be used as a source for future research on MDRPIs and will also be used to guide studies on the prevention of MDRPIs. In addition, another strength of the study is that it may lead to the establishment of guidelines and protocols for the prevention of injuries caused by medical devices used in PICUs and it reveals the importance of nursing care.
In order to prevent the development of MDRPI, it is firstly necessary to select the appropriate size of the instrument for the child, to fix the instrument correctly and to evaluate the fixation tension regularly, to prefer products that minimize tissue damage, and to follow the manufacturer’s recommendations on the use and care of the instrument. However, it is critical to assess the skin and mucosa under and around the medical instrument to detect early signs of pressure. Regular repositioning of the medical instrument will help to reduce the shear force of the pressure at the interface of the skin and the instrument and redistribute the pressure. Emphasis should be given on using a prophylactic dressing under the instrument and discontinuing the use of the instrument as soon as possible to reduce the risk of MDRPI.
Priority should be given to the education of healthcare team members and patient relatives about the developmental potential of PI. Assessment of the child, interventions applied and ongoing care needs should be recorded. All healthcare team members should work together (as a team) for creating and implementing a care plan.
This article suggests that standardized, multicomponent interventions for MDRPI prevention (e.g., the use of risk assessment scales to assess the relocation and repositioning of the device, how often to assess the skin and mucosa under and around the medical device, what type of dressings to use between the medical device and the skin, etc.) should be tested in larger-sampled, randomized, controlled trials for children admitted to intensive care units.