Comparison of Ultrasound Guided Optic Nerve Sheath Diameter Measurements with Other Cranial Imaging Methods (Cranial Computed Tomography and Magnetic Resonance Imaging) in Pediatric Intensive Care Patients
    PDF
    Cite
    Share
    Request
    Research Article
    P: 1-6
    April 2019

    Comparison of Ultrasound Guided Optic Nerve Sheath Diameter Measurements with Other Cranial Imaging Methods (Cranial Computed Tomography and Magnetic Resonance Imaging) in Pediatric Intensive Care Patients

    J Pediatr Emerg Intensive Care Med 2019;6(1):1-6
    1. Marmara Üniversitesi Pendik Eğitim ve Araştırma Hastanesi, Çocuk Yoğun Bakım Kliniği, İstanbul, Türkiye
    2. Marmara Üniversitesi Pendik Eğitim ve Araştırma Hastanesi, Radyoloji Kliniği, İstanbul, Türkiye
    No information available.
    No information available
    Received Date: 04.12.2018
    Accepted Date: 29.01.2019
    Publish Date: 21.03.2019
    PDF
    Cite
    Share
    Request

    ABSTRACT

    Introduction:

    Optic nerve sheath diameter (ONSD) measurements aid in diagnosis of increased intracranial pressure (ICP). Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used modalities for detecting ICP. Lately, ONSD measurements via ultrasound (US) are getting popular as an alternative method due to the ease of performance at the bedside and repeatability. Our study objective was to investigate whether US measurements correlated with CT/MRI counterparts.

    Methods:

    This was a single-center, prospective study. All intubated patients aged 1 month-18 years with a cranial CT/MRI for any indications, who could be scanned ultrasonographically, were included after parental consent. Optic nerve US was performed by a single investigator. CT/MRI ONSDs were measured by a neuro-radiologist. Data obtained from US and CT/MRI scans were compared.

    Results:

    A total of 94 different measurements were obtained. The mean ONSD in US and CT was 4.56±0.66 cm and 4.65±0.72cm on the right side, whereas the mean left ONSD was 4.52±0.63 cm and 4.46±0.67 cm, respectively (p=0.4). Correlation coefficient for right ONSD was r=0.448 (p=0.002) while it was r=0.448 (p=0.001) for left ONSD. Both CT and US measurements showed a linear increase, and the correlation between them was moderate.

    A subgroup of 8 patients who had less than 5 hours between their central imaging and US scan showed strong correlation between measurements for both right and left ONSD [r=0.774, (p=0.024) and r=0.811 (p=0.014), respectively].

    Conclusion:

    There was a correlation between US and CT/MRI ONSD measurements in our study. The correlation was stronger when the time interval was less than 5 hours between measurements. Our findings suggest that US may be a useful, reliable and cost-effective method for assessment and clinical follow-up of increased ICP in intubated pediatric intensive care unit patients.

    Keywords: Optic nerve sheath diameter measurement, computed tomography, magnetic resonance imaging, ultrasound, pediatric intensive care unit, increased intracranial pressure

    References

    1
    Czosnyka M, Pickard JD. Monitoring and interpretation of intracranial pressure. J Neurol Neurosurg Psychiatry. 2004;75:813-21.
    2
    Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, et al. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med. 2007;49:508-14.
    3
    Tsung JW, Blaivas M, Cooper A, Levick NR. A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department. Pediatr Emerg Care. 2005;21:94-8.
    4
    Maissan IM, Dirven PJ, Haitsma IK, Hoeks SE, Gommers D, Stolker RJ. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure. J Neurosurg. 2015;123:743-7.
    5
    Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011;37:1059-68.
    6
    Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care. 2011;15:506-15.
    7
    Hansen HC, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34-40.
    8
    Shofty B, Ben-Sira L, Constantini S, Freedman S, Kesler A. Optic nerve sheath diameter on MR imaging: establishment of norms and comparison of pediatric patients with idiopathic intracranial hypertension with healthy controls. AJNR Am J Neuroradiol. 2012;33:366-9.
    9
    Bäuerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, et al. Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol. 2013;13:187.
    10
    Toscano M, Spadetta G, Pulitano P, Rocco M, Di Piero V, et al. Optic Nerve Sheath Diameter Ultrasound Evaluation in Intensive Care Unit: Possible Role and Clinical Aspects in Neurological Critical Patients’ Daily Monitoring. Biomed Res Int. 2017;2017.
    11
    Amini A, Kariman H, Arhami Dolatabadi A, Hatamabadi HR, Derakhshanfar H, et al. Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure. Am J Emerg Med. 2013;31:236-9.
    12
    Jeon JP, Lee SU, Kim SE, Kang SH, Yang JS, et al. Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography. PloS One. 2017;12:e0183170.
    13
    Kim M-S, Bai S-J, Lee J-R, Choi YD, Kim YJ, et al. Increase in intracranial pressure during carbon dioxide pneumoperitoneum with steep trendelenburg positioning proven by ultrasonographic measurement of optic nerve sheath diameter. J Endourol. 2014;28:801-6.
    14
    Moore CL, Copel JA. Point-of-Care Ultrasonography. N Engl J Med. 2011;364:749-57.
    15
    Ballantyne S, O'neill G, Hamilton R, Hollman A. Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. Eur J Ultrasound. 2002;15:145-9.
    2024 ©️ Galenos Publishing House